V8.2 Modbus TCP: when the qty of bytes received bytes qty is different than the MBAP header, request is rejected and error mentionned when CRC16 calculation is wrong, error is now mentionned and frame is rejected V8.1 Modbus & Terminal: Server connexion are not closed anymore in case of inactivity V8.0 general: Backgroud Colour of some fields were based on Windows palette which could differ. Changed to fixed colour fixe Toolbar (at bottom) truncated depending of screen definition. - FINS fixe a bug on 'change mode button' (RUN mode) - terminal TCP auto reconnexion enhanced when server V7.9 -Terminal Modem GSM PIN code command button improved V7.8 -Terminal TCP Bug fixed: reception was missing control characters - Modbus TCP Bug fixed: Local port fixed generate error when re-connecting to a Modbus TCP server V7.7 -Terminal Allow to send text file small bug fixed on bottom function button which was not sent when Ethernet was selected V7.6 - Client OPC Small change V7.5.5 - Modbus TCP & Terminal Using Ethernet, Local Port number could be selected V7.5.4 - Sysmac-way Bug fixed on Program Upload function (troncated program in particular case) - OPC client Wrong Delay displayed (x1000) adding/removing items enhanvement V7.5.1 - minor bug fixed Some Laptop without serial port could generate an error when Multiway list them in the listbox at initialisation V7.5 - SysmacWay Bug fixed on program upload interrupted by wrong sequence END Editor Buffer cleaned and speed up V7.4 - Terminal Bug fixed on memorized frames sent using control character (in the combo-box history) - FINS Update of unit type V7.3 - SYSMACWAY Terminator optional by check box V7.2.8 - FINS Update of unit type - fixe bug when changing the regional settings (decimal caracter) V7.2.7 -Modbus fixe slave number format (2 digits hexa) V7.2.6 - Fixe an installation problem on English version V7.2.5 - minor bug fixed on Modbus Server reception V7.2.4 - Ethernet communications Teminal UDP/TCP improvment on Ascii/binary mode display. Remote and Local port retained for FINS, Modbus, terminal and Booster V7.2.3 - All communications waiting answer does not keep process ressource anymore - Modbus TCP Fixe problem of adaptor selection when TCP client selected. Server does not disconnect anymore after 120s without communication. It goes back to Listen status - FINS Unit profile update V7.2 - Modbus Any slave number could be simulate by using slave number 00 bug fixed on timer still running when slave - Help menu to www help page V7.1.4 - Sniffer Terminator selected was not displayed - All tabs The response time was related to the size of the editor (refresh speed) refresh method improved. V7.1.3 - Modbus bug fixed on client response V7.1.2 - Terminal minor bug at startup condition with Row or character mode V7.1.1 - Terminal GSM Modem config download enhanced bug fixed when choosing request in the previous list of the combo box V7.0.0 - Design changed - Modbus TCP bug fixed on the length calculated in the response header - CP1H/L Error code added V6.8.3 - FINS add new unit profile - Terminal fixe bug on display Modem frame - sniffer fixe bug on display timestamp twice V6.8.2 - Terminal UDP/TCP connection - Modbus Frames are now splitted by bytes - Sysway DM upload was stopped by a debug line forgotten V6.8.0 - Terminal Modem fonctionnalities implemented (PSTN & GSM) - Modbus TCP Timer enabled - General Buttons hightlighted when pressed V6.7.4 - Modbus: fixe Bux when editor filled fixe bug on Button SEND when not connected V6.7.3 - Terminal: line command enhanced V6.7 - FINS UDP: default Local port 9001 to avoid conflict with Cx-server bug fixed on wrong local port opened DA1 automatically calculated when ping OK When Fins Request received (ICF <82) there is no error code field to control (ex: SEND from an PLC) - new unit profile updated (for read unit model command) V6.6 - Ethernet adapter selection allowed - local help on text (hyperlink style) - local & remote IP revised - Modbus Slave correction on function code 01 02 06 - design V6.5 - Toolbus: fixe connection problem when serial interface used (ex: bluetooth) - Modbus: Option fill blank with 0 Fixe bug on Modbus function code 0F (size +1 was written) TCP Server disconnection after 120s without communications (keep alive) TCP server switch to listen state after client disconnection. V6.4 (minor) - Master/slave & Client/Server splited - Local & Remote Port managment revised V6.3 - Real Modbus slave RTU & TCP (instead of automated response) - TimeStamp information improved V6.2.1 (minor) - small bug displayed when connecting with V700 V6.2 - Bug introduced by V6.00 in the Compoway protocole. Response was wrongly interpreted (ascii convertion) V6.1 - Log all exchange in to file saved in ...\Multiway\logfile.txt - Timer display problem fixed V6.0 - V700 and Compoway split into the same tab - direct Ping command in FINS & Modbus TCP tab (golf) - check if 2 Ethernet cards used by the computer then warning message when TCP/UDP message sent V5.4 - Sniffer improvement (in setup) - Modbus combo box bug fixed - Editor size increased - serial port list refreshable (USB) - wiring revised V5.2 - New Tab 'OPC Client' with array tag and reporting - Booster UDP - FINS commande added create I/O Table Read error log Read Unit Model, Lot n°, Unit version DM Upload/Download V4.3 - RTS CTS led activity (RTS can be forced) - Compoway/F toolbar command V4.2 - fixe socket close ( when FINS TCP used) - fixe ComPort problem on sniffer when port disappear (USB convertor) - Ascii display was forgoten in HostLink FINS editor V4.1 - Bug: one debug line was left in Terminal mode - ASCII editor enhanced (upload/download) V4.0 - Program Upload/Download to/from TXT file( Sysway only) - DM Upload/download from/to CSV file (Sysway and FINS) - Modbus slave according to the slave No specified - FINS error code enhanced - serial port Number limited to existing port V3.1 - FINS command detailled with example - RTS control - ASC02, BCC review... V3.0 - Toolbus protocol (auto-detect procedure) - Ethernet TCP - Only English until now - all tabs look similar - list of Fins and sysway error code - omron cable drawing -Terminal improvements V2.6 - autodetect Sysmac-way, FINS Modbus and modem - sniffer improved - com fomat stored V2.5 - 2 more tabs: sniffer allow to watch exchange between 2 RS232C devices (for instance PLC and modem) booster allow to load a communication with a slave (omron, modbus or what ever) using RS232C. Only communication error are displayed. This can be used to detect noise on the line. - BCC of V700/V720 revised - Modbus slave or master emulation - all Tabs setup parameter saved